Description The MERLIN CP Monitor is a compact unit housed within, or adjacent to, a Test Station or Bond Box. It collects Cathodic Protection (CP) data and communicates (via either an internal or external antenna) using the cellular network. MERLIN CP monitors collect CP data automatically, check that it is within specification and report immediately if an alarm threshold is exceeded. They can be deployed anywhere on the pipeline network where it is important to record pipe-to-soil potentials or measurements of bonding or interfering currents. Alternatively it may simply be that certain measurement points on the pipeline create risks to CP technicians, such as at busy road or rail crossings, or are difficult to access, such as on private land. At these points remote monitoring is very cost-efficient and can improve safety. Two key features of the Abriox system are: Cellular telephone control AC monitoring on all channels to identify a possible corrosion threat and protect the workforce from dangerous voltages or currents.  All data is automatically transmitted in a management report to the system HQ where it is available on-line using Abriox’s MERLIN iCPSM software. iCPSM provides access from any Internet-enabled PC to a passwordprotected CP database, unique to each customer. Users can configure and control MERLIN monitors, view CP data in graphical and numerical formats or export data for further analysis and archiving.   Benefits DC and AC monitoring for full corrosion prevention. Fully automatic system - data sent in automatically, wirelessly. Email or text message alarm when CP levels are inadequate. Reduced cost of measurement, especially at remote locations. Engineering time freed up for data interpretation and follow-up. Reduced risk to workforce at dangerous or remote sites. Zero carbon footprint for CP monitoring. no vehicle surveys required, fully automatic system. Small size for deployment at test stations, bonds etc.  

Created by: Pipeline Corrosion Control

Last updated 12/2025

Explore Related topics

Description

Description The MERLIN CP Monitor is a compact unit housed within, or adjacent to, a Test Station or Bond Box. It collects Cathodic Protection (CP) data and communicates (via either an internal or external antenna) using the cellular network. MERLIN CP monitors collect CP data automatically, check that it is within specification and report immediately if an alarm threshold is exceeded. They can be deployed anywhere on the pipeline network where it is important to record pipe-to-soil potentials or measurements of bonding or interfering currents. Alternatively it may simply be that certain measurement points on the pipeline create risks to CP technicians, such as at busy road or rail crossings, or are difficult to access, such as on private land. At these points remote monitoring is very cost-efficient and can improve safety. Two key features of the Abriox system are: Cellular telephone control AC monitoring on all channels to identify a possible corrosion threat and protect the workforce from dangerous voltages or currents.  All data is automatically transmitted in a management report to the system HQ where it is available on-line using Abriox’s MERLIN iCPSM software. iCPSM provides access from any Internet-enabled PC to a passwordprotected CP database, unique to each customer. Users can configure and control MERLIN monitors, view CP data in graphical and numerical formats or export data for further analysis and archiving.   Benefits DC and AC monitoring for full corrosion prevention. Fully automatic system - data sent in automatically, wirelessly. Email or text message alarm when CP levels are inadequate. Reduced cost of measurement, especially at remote locations. Engineering time freed up for data interpretation and follow-up. Reduced risk to workforce at dangerous or remote sites. Zero carbon footprint for CP monitoring. no vehicle surveys required, fully automatic system. Small size for deployment at test stations, bonds etc.   Features Compact size - quick and easy to install, typically 20 minutes on site Daily CP level check (hourly optional for problem solving) Alarms reported immediately (user preset thresholds for all channels) Weekly report gives min, max and average of all channels for the week 5-year life, batteries replaceable Sealed, weatherproof unit with robust lightning protection and wide operational temperature for all extremes Test and set up from cellular telephone using text messaging Web-based user interface with graphical/tabular displays and data export   GSM (SMS) Communications Batteyry Backup Test and set up from cell phone usingtext messaging. 5 year life, replaceable battery module. User Alerts Synchronized Interruption Alarms reported immediately (user presetthresholds for all channels). Pair of relay contacts, normally closed. Contacts open whilst channel 2 is read. Electrical Supply Monitoring Custom Reports Alarm sent when protection levels inadequate – so that protection can quickly be restored to the pipeline. Data automatically archived and presented in custom report formats or exported to other standard applications. IP Rating Weight The MERLIN CP Monitor is IP67 rated. Offering protection against falling dirt, rain, sleet, snow, windblown dust, splashing, hose-directed water and temporary immersion.  450g (1lb) Daily or Weekly Reports Lightning Protection Weekly report gives min, max and averageof all channels for the week Surge protection on all external inputs and outputs. 2,500A at 3,000V (8/20us). Additional protection using recommended surge arrestors. Operational Remperatures   -40°C to +85°C (-40°F to +185°F). 100% condensing humidity.   Lightning Protection Testing performed on the new MERLIN design showed that: A “naked” MERLIN easily survives 2500A at 3kV (8/20us pulse) via AC or from the pipeline – a substantial surge. With Abriox’s recommended external surge arrestors in place, the MERLIN withstands10kA, 10kV without damage - a massive surge.  Even bigger surges (29kA) can be survived by MERLIN - but the external surge arrestors may be blown to pieces! Technical Specification The MERLIN Transformer Rectifier Monitor is a compact unit designed to monitor and report the operation of a rectifier. Its key features are: Alarms and periodic reports sent to a central HQ using GSM SMS communication Fully independent monitoring channels (allow high-side or low-side shunt and accurate ON potential measurement) Installation by cellphone Remote control of rectifier output from cellphone and/or software. Physical Dimensions Physical Dimensions (H x W x D) 5” x 3.5” x 2” Weight 1lb IP Rating IP67 Operating Temperature -40°F to +185°F 100% condensing humidity Lightning Protection Surge protection on all external inputs and outputs 2,500A at 3,000V (8/20us) Backup Battery 5-year life, replaceable battery module Communications Cellular (GSM/SMS) Software Management iCPSM (web based) or CPSM (PC based) Inputs Two pipe-to-soil inputs 10 MOhm input impedance ± 4V DC with AC rejection 1mV resolution 0-70V AC RMS, 10mV resolution Current shunt input 0-100mV 0.01mV resolution AC and DC current measured All monitoring channels are fully independent Outputs Pair of relay contacts, normally closed Contacts open while pipe to soil input 2 is read Contacts rated at 1A at 30V DC   Typical installation locations for the MERLIN CP Monitor include: mid-points between rectifiers or pipeline terminations (low CP levels), pipeline crossings or corridors (sources of interference from foreign systems), critical bonds between pipelines (the direction of the bond current can even be monitored), isolation joints (to check potentials either side of the IJ), pipelines close to (or parallel with) power lines (sources of AC interference) and rectifier drain points (to check rectifier output levels).     Measurements   Pipe-to-Soil 1 Pipe-to-Soil 2orInstant OFF  Coupon Current orBond Current    DC AC DC AC DC AC 1 Channel 2 Channel 3 Channel Pipe-to-soil potential measurements (Premium and higher) at the rectifier require a reference cell and relay. Remote synchronization (Super and Excel) require a MERLIN solid state Interrupter.
img

This Premium Product is included in plans

£ 799.00 £ 999.00 20% off

Related Modules

Pipeline Corrosion in World Wide

Signup for Newsletter