Dairyland PCRX

Building on Dairyland's industry-leading product lines, the PCRX represents the next technological leap forward in decoupling technology. Using sophisticated design techniques that represent the work of numerous leading experts around the world, the PCRX’s new camouflage technology renders it virtually invisible to interrupted survey testing.  Like our other decouplers, the PCRX is a solid-state, maintenance-free device designed to simultaneously provide DC decoupling and AC continuity/grounding when used with cathodically protected structures, such as pipelines, tanks, grounding systems, and cable casings. Commonly used to decouple electric equipment from grounding systems, for AC mitigation projects, or other isolation and grounding applications, the PCRX provides safety grounding while also isolating your cathodically protected structure, improving CP system performance.   

Created by: Pipeline Corrosion Control

Last updated 11/2025

Explore Related topics

Description

Building on Dairyland's industry-leading product lines, the PCRX represents the next technological leap forward in decoupling technology. Using sophisticated design techniques that represent the work of numerous leading experts around the world, the PCRX’s new camouflage technology renders it virtually invisible to interrupted survey testing.  Like our other decouplers, the PCRX is a solid-state, maintenance-free device designed to simultaneously provide DC decoupling and AC continuity/grounding when used with cathodically protected structures, such as pipelines, tanks, grounding systems, and cable casings. Commonly used to decouple electric equipment from grounding systems, for AC mitigation projects, or other isolation and grounding applications, the PCRX provides safety grounding while also isolating your cathodically protected structure, improving CP system performance.    THRESHOLD VOLTAGE -4.5/+3.5 -5.5/+2.5 AC STEADY-STATE CURRENT (amperes - rms) 50/60Hz 45A LIGHTNING SURGE CURRENT 100kA crest (8 x 20 µs waveform) ENVIRONMENTAL RATING NEMA 4X (standard) Ambient Temperature Range: -40C to +50C (-40 to +122F) IP66 HAZARDOUS (CLASSIFIED) AREAS ANSI/ISA: Class I, Division 2, Groups A, B, C, D ATEX: Zone 2, Group IIC IECEx: Zone 2, Group IIC UKEx: Zone 2, Group IIC   AC Fault Current (amperes-rms) 50/60 Hz Model 30 cycles PCRX-5KA 5,000 PCRX-10KA 10,000 PCRX-15KA 15,000 Model Number Description Chart Class I, Div. 2, Groups A, B, C, D and Zone 2, Group IIC. Class & Division System: UL (United States) and C-UL (Canada) Effective Ground Fault Current Path per: NFPA 70 (US National Electric Code – NEC): Article 250.4(A)(5) CSA C22.1 (Canadian Electric Code, Part I): 10-100 & 10-500 Isolation of Objectionable DC Ground Currents per: NFPA 70: Article 250.6(E) CSA C22.1: 10-100 & 10-500 Hazardous Location Use: Class 1, Division 2, Groups A, B,C,D by UL & C-UL per: UL 121201, 9th Ed. and CSA C22.2 No.213-17 Safety Requirements for Electrical Equipment per: UL 61010-1, 3rd Ed. & CSA C22.2 No. 61010-1 Overvoltage Protection from Impulse (Lightning) Current: 100kA (8 x 20µs) Enclosure Rating: NEMA 4X • Temperature Range: -40°C to +50°C (-40°F to +122°F) Ambient Pressure of 80 kPa (0.8 bar) to 110 kPa (1.1 bar) Max Altitude: 2000 meters Relative Humidity: 0-100% noncondensing Outdoor use Pollution Degree 2 CSA C22.1 (Canadian Electric Code, Part I): 10-100 & 10-500 Zone System: ATEX / IECEx / UKEx (Europe / International / UK). ATEX per directive 2014/34/EU (Equipment for use in Potentially Explosive Atmospheres): Zone 2, Group IIC, Increased Safety “ec” EN IEC 60079-0: 2018 EN IEC 60079-7: 2015+A1:2018 IEC 60079-0: 2017 IEC 60079-7: 2017 Overvoltage Protection from Impulse (Lightning) Current: 100kA (8 x 20µs) Temperature Range: -40°C to +50°C Enclosure Rating: IP66
img

This Premium Product is included in plans

£ 799.00 £ 999.00 20% off

Related Modules

Pipeline Corrosion in World Wide

Signup for Newsletter